Build and Test an Ethernet Cable
This is the complete step-by-step sequence from the classroom presentation.
Wear safety glasses when trimming conductors. Work only on an unplugged cable. Use the demonstrated stripper, cutter, and crimper. Keep wire clippings off the floor.

Tools
Cable, matching 8P8C plugs, stripper/cutter, crimper, tester, ruler, and scrap container.
Figure 1. Tools. Open source and CC BY 4.0 licence.

T568B order
Use the same order on both ends for this straight-through cable.
Figure 2. Open source and licence.
1 white-orange2 orange3 white-green4 blue5 white-blue6 green7 white-brown8 brown
Procedure
0
Measure and cut
Leave enough cable for a gentle route and a small service loop.
1
Remove the outer jacket
Strip about 25 to 40 mm. Cut lightly. Do not nick the eight insulated conductors.
2
Inspect every conductor
If copper is exposed or insulation is cut, remove the damaged section and start again.
3
Untangle and flatten
Separate the four pairs. Untwist only the length needed to reach the plug.
4
Arrange T568B
Place all eight conductors in the colour order shown above.
5
Trim to an even 13 mm
Pinch the order between your fingers. Cut the ends straight and even.
6
Insert and verify
Clip down, gold pins up, white-orange on the left. Every wire reaches the front. About 6 mm of jacket enters the plug.
7
Crimp
Insert the plug fully into the correct crimper slot. Squeeze completely using the demonstrated tool procedure.
8
Inspect the termination
All contacts sit evenly. The strain relief grips the jacket. Gently tug the cable.
9
Finish the other end and test
Use T568B again. A good tester shows pins 1 through 8 in the same order at both ends.

Steps 1 and 2
Remove only the jacket, then inspect the inner insulation.
Figure 3. Open source and licence.

Step 3
Separate the pairs and keep the untwisted length short.
Figure 4. Open source and licence.

Steps 4 to 6
Order, flatten, trim, insert, and check through the clear plug.
Figure 5. Open source and licence.

Steps 7 and 8
Crimp fully. Check contact height and strain relief before testing.
Figure 6. Public-domain visual sequence. Open source.

Step 9
Test for correct order, opens, shorts, reversals, crossed pairs, and split pairs.
Figure 7. Open source and licence.
Final quality check
- T568B order on both ends.
- No exposed copper or cut insulation.
- Every conductor reaches the front.
- Jacket is under the strain relief.
- All contacts are evenly crimped.
- Tester shows 1 through 8 in order.
Evidence
Take five photos: stripped jacket, flattened T568B order, head-on view before crimping, finished connector, and tester result.